HES
HES 5200C-LBSM Complete Pac Electric Strike Kit with Latchbolt Strike Monitor
$199.99
In Stock
The HES 5200C-LBSM is the fully monitored version of the HES 5200 Complete Pac. It ships as one kit: the 5200 electric strike body, the 501 faceplate for cylindrical locksets in ANSI-prepped metal jambs, the 501A faceplate for cylindrical locksets or spring latches in aluminum frames, the 12 V and 24 V plug-in pigtails, and the trim enhancer. One part number covers metal, wood, and aluminum frames without a second faceplate order.
Why LBSM instead of LBM: the LBM version has one switch that reports whether the latchbolt is projected into the keeper. The LBSM adds a second, independent switch on the strike keeper itself, so your access control or alarm panel gets two separate signals: door latched (latchbolt monitor) and strike secured (strike monitor). Specify the LBSM when the system has to prove the opening is actually locked rather than merely closed: high-security doors, doors supervised for forced-entry or held-open alarms, and any door where panel logic needs to tell "latch in" from "keeper locked." If you only need door-closed status, the 5200C-LBM does that for less.
Installation: the 5200 series is built around in-frame horizontal adjustability. After the strike is mounted you can move the keeper up to 3/16" toward or away from the door stop to line up with the latchbolt instead of re-cutting the pocket. The body is 1-3/16" deep, non-handed, with an internally mounted solenoid and plug-in connector. It accepts 5/8" to 3/4" throw latchbolts (3/4" with a 1/8" door gap) and uses the standard 4-7/8" ANSI strike preparation with the 501 or 501A faceplate.
Fail-safe or fail-secure: the unit ships in fail-secure mode. Converting to fail-safe is a two-screw change on the back of the strike body (loosen, move to the top of the slot, retighten), documented in the HES installation instructions.
Electrical: 240 mA at 12 VDC or 120 mA at 24 VDC, continuous duty. 12-16 VAC and 24 VAC are permitted for intermittent duty only (10% maximum duty cycle, 2 minutes maximum on-time), so an AC supply is not suitable for a fail-safe installation. HES specifies a UL 294 Class 2 power-limited supply or a listed access control unit, and recommends inductive-kickback protection (HES 2005M3 SMART Pac III or 2001M bridge rectifier). Both monitor switches are rated 500 mA at 30 V with Common / Normally Open / Normally Closed leads (latchbolt monitor: white / orange / green; strike monitor: brown / blue / yellow). Wire gauge per HES, round trip: 12 VDC uses 18 AWG to 200 ft, 16 AWG to 300 ft, 14 AWG to 400 ft; 24 VDC uses 20 AWG to 200 ft, 18 AWG to 300 ft, 16 AWG to 400 ft.
Ratings: ANSI/BHMA A156.31 Grade 1. UL 294 Listed. UL 1034 Burglary-Resistant Listed with 1,500 lbs static strength and 70 ft-lbs dynamic impact. Manufacturer endurance rating 1,000,000 cycles (UL 1034 endurance level 250,000 cycles). RoHS compliant. Per HES, the monitor options were not evaluated under the UL 294 / UL 1034 / ULC-60839-11-1 listings and are designated for indoor use. No fire-rating listing appears on the HES data sheet; confirm with your AHJ before specifying this strike on a fire-rated opening.
In the box: 5200 electric strike body (LBSM), 501 faceplate, 501A faceplate, faceplate mounting screws (#12-24 x 1/2"), 12 V and 24 V plug-in pigtails (HES 2007M), trim enhancer with #4-40 screws (HES 5200-105), HES installation instructions. Not included: power supply, lockset, SMART Pac or rectifier, and the 502 / 503 / 504 faceplates (ordered separately for long-plate and wood-frame preps).
Does not fit: mortise locks with a deadbolt (see the HES 1006 series), rim exit devices (see HES 9400 / 9600), latchbolts over 3/4" throw, and openings that require a fire-rated strike.
New in the unopened HES retail box. Covered by the Rapid Security Hardware 1-Year Guarantee and our 30-day return policy.